Model 640 Weigh Tronix Calibration Procedure
Model: 640
1. Press the On/Off button and the greeting “Hello” should arrear on the screen and then the scale will
return to zero. ( Make sure the scale is empty and hooked up to the towing vehicle )
2. From the G/N mode, press and hold the HOLD/MENU key for three beeps ( 3 sec. ) then release…
SET.PAS is displayed
3. Press the RM button until the number 6 is displayed then press the HOLD/MENU button to move
the cursor one position.
4. Press the RM button until the number 4 is displayed then press the HOLD/MENU button to move
the cursor one position.
5. Press the RM button until the number 0 is displayed then press the PRINT/SELECT button once…
CONFIG should be displayed.
6. Press the HOLD/MENU button until….SPAN is displayed
7. Press the PRINT/SELECT button and now the current weight should be displayed.
8. With either a calibrator or some known weight, put an appropriate weight onto the scale… and the
current weight is displayed.
9. Press the RM key to increase the weight or the M+ key to decrease the weight accordingly.
10. Once the appropriate weight value is shown, press the PRINT/SELECT button… SPAN should
be displayed on the screen.
11. Press the G/N button until the indicator returns to the gross weighing mode. Calibration of the
scale is then complete.